For the ultimate precision in the elemental and chemical analysis of materials, customers depend on Oxford Instruments x-ray sources. Whether verifying chemical composition of advanced metals alloys, or protecting consumers from hazardous chemicals in food, to detecting the chemical make-up of Martian soils, Oxford x-ray sources provide safe, stable operation and long life.


Product Name Part NumberOutline DrawingTargetOperating Range (kV)Max Anode Current (mA)Max Anode Power (W)Max Filament Current (A)Spot Size (µm)**  
X-ray Tube, Neptune Pkg, W, HP 93212*8250W10 - 502.01002.4175 Max. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
*Includes a thermal switch which adds an additional level of protection to the cooling system safeguards.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part NumberOutline DrawingTargetOperating Range (kV)Max Anode Current (mA)Max Anode Power (W)Max Filament Current (A)Spot Size (µm)**  
X-ray Tube, Jupiter Pkg, W, HP 93000*8166W10 - 501.0501.7165 Max. Add to quote list
X-ray Tube, Jupiter Pkg, Mo, HP 930018166Mo10 - 501.0501.7150 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, Mo, STD, O-ring 930468208Mo4 - 501.0501.31000 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, W, HP 93069*8166W10 - 501.0501.770 Max. Add to quote list
X-ray Tube, Jupiter Pkg, Mo, HP, VacFlange 93079*8203Mo10 - 501.0501.7150 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, W, VHP 93089*8166W10 - 501.0501.750 Max. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
*Includes a thermal switch which adds an additional level of protection to the cooling system safeguards.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part NumberOutline DrawingTargetOperating Range (kV)Max Anode Current (mA)Max Anode Power (W)Max Filament Current (A)Spot Size (µm)**  
X-ray Tube, Apogee Pkg, W, VHP 93501*8243W10 - 501.01.0501.735 Nom. Add to quote list
X-ray Tube, Apogee Pkg, Mo, VHP, 55kV 93000058243Mo10 - 551.01.0501.735 Nom. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
*Includes a thermal switch which adds an additional level of protection to the cooling system safeguards.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part NumberOutline DrawingTargetOperating Range (kV)Max Anode Current (mA)Max Anode Power (W)Spot Size (µm)**  
X-ray Tube, 3000 Potted, W, 15W, STD 900048145W4 - 300.5151.31000 Typ. Add to quote list
X-ray Tube, 3000 Potted, W, 9W, STD 900368053W4 - 300.391.31000 Typ. Add to quote list
X-ray Tube, 3000 Potted, W, 6W, STD 901168053W4 - 300.261.31000 Typ. Add to quote list
X-ray Tube, 3000 Potted, Fe, STD 901188052Fe4 - 101.5151.31000 Typ. Add to quote list
X-ray Tube, 3000 Potted, W, 2.0mA,Soft X 901468057W5 - 13.62.027.22.01000 Typ. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part NumberOutline DrawingTargetOperating Range (kV)Max Anode Current (mA)Max Anode Power (W)Max Filament Current (A)Spot Size (µm)**  
X-ray Tube, 1500 Glass, W, 5mA, IND 900468162W4 - 505.02502.4500 Typ. Add to quote list
X-ray Tube, 1500 Glass, Mo, HP 900688188Mo10 - 501.0501.7150 Typ. Add to quote list
X-ray Tube, 1500 Glass, W, HP 900838188W10 - 501.0501.7150 Typ. Add to quote list
X-ray Tube, 1500 Glass, Fe, 5mA, IND 900988162Fe4 - 505.02002.4500 Typ. Add to quote list
X-ray Tube, 1500 Glass, W, HP 900998189W10 - 501.0501.770 Max. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part NumberOutline DrawingTargetOperating Range (kV)Max Anode Current (mA)Max Anode Power (W)Max Filament Current (A)Spot Size (µm)**  
X-ray Tube, 1501 Glass, Cr, HP, 2mA 901228257Cr4 - 502.0752.4175 Max. Add to quote list
View Quote List
Product Name Part NumberOutline DrawingTargetOperating Range (kV)Max Anode Current (mA)Max Anode Power (W)Max Filament Current (A)Spot Size (µm)**  
X-ray Tube, 1550 Glass, W, VHP 902018242W10 - 501.0501.750 Max. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part NumberOutline DrawingTargetOperating Range (kV)Max Anode Current (mA)Max Anode Power (W)Power DensitySpot Size (µm)**  
X-ray Microfocus, UltraBright, 60kV, Cu 96000*8236Cu20 - 602.0601.5W/µm20 Max. Add to quote list
X-ray Microfocus, UltraBright, 60kV, Mo 96002*8236Mo20 - 602.0601.5W/µm20 Max. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
*Includes a thermal switch which adds an additional level of protection to the cooling system safeguards.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part NumberOutline DrawingTargetOperating Range (kV)Max Anode Current (mA)Max Anode Power (W)Power DensitySpot Size (µm)**  
X-ray Microfocus, Nova 600, 60kV, Mo 96016*8240Mo20 - 602.0601.5W/µm20 Max. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
*Includes a thermal switch which adds an additional level of protection to the cooling system safeguards.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List