Part of the Oxford Instruments Group
Expand
XRF Thickness Measurement

XRF Thickness Measurement

For the ultimate precision in the elemental and chemical analysis of materials, customers depend on Oxford Instruments x-ray sources. Whether verifying chemical composition of advanced metals alloys, or protecting consumers from hazardous chemicals in food, to detecting the chemical make-up of Martian soils, Oxford x-ray sources provide safe, stable operation and long life.


Product Name Part NumberOutline DrawingTargetOperating Range (kV)Max Anode Current (mA)Max Anode Power (W)Max Filament Current (A)Spot Size (µm)**  
X-ray Tube, Neptune Pkg, Mo, HP 93211*8250Mo10 - 502.01002.4175 Max. Add to quote list
X-ray Tube, Neptune Pkg, W, HP 93212*8250W10 - 502.01002.4175 Max. Add to quote list
X-ray Tube, Neptune Pkg, Rh, HP 93221*8250Rh10 - 502.01002.4375 Max. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
*Includes a thermal switch which adds an additional level of protection to the cooling system safeguards.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part NumberOutline DrawingTargetOperating Range (kV)Max Anode Current (mA)Max Anode Power (W)Max Filament Current (A)Spot Size (µm)**  
X-ray Tube, Jupiter Pkg, W, HP 93000*8166W10 - 501.0501.7165 Max. Add to quote list
X-ray Tube, Jupiter Pkg, Mo, HP 930018166Mo10 - 501.0501.7150 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, Ag, STD 930258166Ag4 - 501.0501.31000 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, Au, STD 930358166Au10 - 501.0251.31000 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, Mo, STD, O-ring 930468208Mo4 - 501.0501.31000 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, Cu, HP 930488166Cu10 - 501.0501.7150 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, Rh, HP 930578166Rh10 - 501.0501.7180 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, Rh, HP, VacFlange 930598203Rh10 - 501.0501.7180 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, W, HP 93069*8166W10 - 501.0501.770 Max. Add to quote list
X-ray Tube, Jupiter Pkg, Cr, HP 930708166Cr10 - 501.0501.7200 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, W, HP, VacFlange 930718203W10 - 501.0501.7150 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, Ti, STD 930728166Ti4 - 501.0501.31000 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, Pd, HP 930738166Pd10 - 501.0501.7200 Max. Add to quote list
X-ray Tube, Jupiter Pkg, Cu, HP, VacFlange 93078*8203Cu10 - 501.0501.7175 Max. Add to quote list
X-ray Tube, Jupiter Pkg, Mo, HP, VacFlange 93079*8203Mo10 - 501.0501.7150 Typ. Add to quote list
X-ray Tube, Jupiter Pkg, W, VHP 93089*8166W10 - 501.0501.750 Max. Add to quote list
X-ray Tube, Jupiter Pkg, Mo, VHP 93095*8166Mo20 - 501.0501.755 Max. Add to quote list
X-ray Tube, Jupiter Pkg, Fe, STD 2mA 50W 93512*8166Fe4 - 502.0501.41000 Typ. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
*Includes a thermal switch which adds an additional level of protection to the cooling system safeguards.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part NumberOutline DrawingTargetOperating Range (kV)Max Anode Current (mA)Max Anode Power (W)Max Filament Current (A)Spot Size (µm)**  
X-ray Tube, Apogee Pkg, Cu, VHP 93500*8243Cu10 - 501.0501.735 Nom. Add to quote list
X-ray Tube, Apogee Pkg, W, VHP 93501*8243W10 - 501.0501.735 Nom. Add to quote list
X-ray Tube, Apogee Pkg, Mo, VHP 93502*8243Mo10 - 501.0501.735 Nom. Add to quote list
X-ray Tube, Apogee Pkg, Rh, VHP 93504*8243Rh10 - 501.0201.735 Nom. Add to quote list
X-ray Tube, Apogee Pkg, Cu, VHP 93508*8243Cu10 - 501.0501.735 Nom. Add to quote list
X-ray Tube, Apogee Pkg, Cu, VHP 93510*8243Cu10 - 501.0501.735 Nom. Add to quote list
X-ray Tube, Apogee Pkg, Mo, VHP 93511*8243Mo10 - 501.0501.735 Nom. Add to quote list
X-ray Tube, Apogee Pkg, Mo, VHP, 55kV 93000058243Mo10 - 551.0501.735 Nom. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
*Includes a thermal switch which adds an additional level of protection to the cooling system safeguards.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part NumberOutline DrawingTargetOperating Range (kV)Max Anode Current (mA)Max Anode Power (W)Filament Current LimitSpot Size (µm)**  
X-ray Tube, 3000 Potted, W, 15W, STD 900048145W4 - 300.5151.31000 Typ. Add to quote list
X-ray Tube, 3000 Potted, Ti, STD 900208052Ti4 - 300.5151.31000 Typ. Add to quote list
X-ray Tube, 3000 Potted, W, 9W, STD 900368053W4 - 300.391.31000 Typ. Add to quote list
X-ray Tube, 3000 Potted, Mo, 15W, STD 900428195Mo4 - 300.5151.31000 Typ. Add to quote list
X-ray Tube, 3000 Potted, Mo, STD,180 Deg 900538204Mo4 - 151.0151.31000 Typ. Add to quote list
X-ray Tube, 3000 Potted, Au, STD 900578156Au4 - 300.5151.31000 Typ. Add to quote list
X-ray Tube, 3000 Potted, W, 6W, STD 901168053W4 - 300.261.31000 Typ. Add to quote list
X-ray Tube, 3000 Potted, Fe, STD 901188052Fe4 - 101.5151.31000 Typ. Add to quote list
X-ray Tube, 3000 Potted, Pd, STD 901458054Pd4 - 400.392.01000 Typ. Add to quote list
X-ray Tube, 3000 Potted, W, 2.0mA,Soft X 901468057W5 - 13.62.027.22.01000 Typ. Add to quote list
X-ray Tube, 3000 Potted, Rh, 9W, STD 901518063Rh4 - 300.392.01000 Typ. Add to quote list
X-ray Tube, 3000 Potted, Ag, 9W, STD 901528063Ag4 - 300.392.01000 Typ. Add to quote list
X-ray Tube, 3000 Potted, Mo, 9W, STD 901538063Mo4 - 300.392.01000 Typ. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part NumberOutline DrawingTargetOperating Range (kV)Max Anode Current (mA)Max Anode Power (W)Max Filament Current (A)Spot Size (µm)**  
X-ray Tube, 1500 Glass, Rh, HP, Long Ext 900118194Rh10 - 501.0501.7150 Max. Add to quote list
X-ray Tube, 1500 Glass, Cr, HP 900348188Cr10 - 501.0501.7200 Typ. Add to quote list
X-ray Tube, 1500 Glass, W, 5mA, IND 900468162W4 - 505.02502.4500 Typ. Add to quote list
X-ray Tube, 1500 Glass, Mo, HP 900688188Mo10 - 501.0501.7150 Typ. Add to quote list
X-ray Tube, 1500 Glass, Cu, HP 900698188Cu10 - 501.0501.7150 Typ. Add to quote list
X-ray Tube, 1500 Glass, Rh, HP 900778188Rh10 - 501.0501.7150 Typ. Add to quote list
X-ray Tube, 1500 Glass, W, HP 900838188W10 - 501.0501.7150 Typ. Add to quote list
X-ray Tube, 1500 Glass, Fe, 5mA, IND 900988162Fe4 - 505.02002.4500 Typ. Add to quote list
X-ray Tube, 1500 Glass, W, HP 900998189W10 - 501.0501.770 Max. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List
Product Name Part NumberOutline DrawingTargetOperating Range (kV)Max Anode Current (mA)Max Anode Power (W)Max Filament Current (A)Spot Size (µm)**  
X-ray Tube, 1501 Glass, Rh, HP, 2.5mA 900158194Rh4 - 502.5502.4200 Max. Add to quote list
X-ray Tube, 1501 Glass, Cr, HP, 2mA 901228257Cr4 - 502.0752.4175 Max. Add to quote list
View Quote List
Product Name Part NumberOutline DrawingTargetOperating Range (kV)Max Anode Current (mA)Max Anode Power (W)Max Filament Current (A)Spot Size (µm)**  
X-ray Tube, 1550 Glass, Cu, VHP 902008242Cu10 - 501.0501.750 Max. Add to quote list
X-ray Tube, 1550 Glass, W, VHP 902018242W10 - 501.0501.750 Max. Add to quote list
X-ray Tube, 1550 Glass, Mo, VHP 902028242Mo10 - 501.0501.750 Max. Add to quote list
X-ray Tube, 1550 Glass, Rh, VHP 902048242Rh10 - 501.0501.750 Max. Add to quote list

Note: Part number specific copies of outline drawings and product specification sheets are available.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)

View Quote List