The Jupiter 5000 Series is a 50kV, 50W packaged X-ray tube designed for applications where high flux density and continuous operation are important.
Utilizing our highly stable and high intensity X-ray tube technology, the Jupiter 5000 Series is ideal for medical imaging applications and most industrial inspection and non-destructive testing applications that require high resolution, including PCB assembly, battery, plastic, metal and mechanical parts inspection.
The 5000 Series features a stainless steel, lead-lined package that is filled with dielectric oil, which enables the unit to provide maximum X-ray shielding and heat dissipation. The design includes high voltage and filament connectors, making it ideal for plug and play operation.
The Jupiter 5000 Series is available in a wide range of spot sizes, targets and price points to meet your needs.
Operating Voltage Range | 50kV max. Lower kV cutoff varies by product. See product ordering table. |
Maximum Power | 50W (except 93035) |
Maximum beam current | 1.0mA (except 93512) |
Focal spot size | See Product Quote table below. |
Maximum Filament Current | See Product Quote table below. |
Filament Voltage | 2.0V (nominal) |
Focus to Object Distance (FOD) | See diagram on Datasheet. |
Window material and thickness | Be @ 127µm |
Cone of illumination (unobstructed) | 23° |
Window diameter (unobstructed) | 11.43mm (.450") |
Target material | See Product Quote table below. |
Target angle | 12° |
Stability | 0.2% 4 hours |
Polarity | Grounded cathode |
Ambient operating temperature | 0°C to 40°C |
Cooling | 150 CFM forced air recommended. Longest lifetimes are achieved by keeping case temperature as low as possible in operation. Maximum temperature: 55°C. Contact sales@oxinst.com to discuss your specific cooling applications. |
Shielding | 0.25mR/hr @ 2” (except at HV connection) |
Dimensions | 180mm L x Ø70mm (7.09” L x Ø2.76”) |
Weight | 2.26 kg (5.0 lbs) |
Storage Conditions | -10°C to 55°C Barometric Pressure: 50-106kPa; Humidity: 10-90% (no condensation) Condensation on Be window will cause window corrosion, vacuum loss and X-ray tube failure |
Wide operating range - enables optimal image contrast
Stable X-ray output - delivers high precision measurements
Low attenuation beryllium window - ensures high transmission of low energy X-rays
Fully-shielded compact package - eliminates X-ray leakage and easily integrates into your system
1. In the table below, please click the “Add to quote list” button for all products that you would like quoted.
2. Scroll to the bottom of the table and click the green “My Quote List” button to visit the submission form page.
Product Name | Part Number | Outline Drawing | Target | Operating Range (kV) | Max Anode Current (mA) | Max Anode Power (W) | Max Filament Current (A) | Spot Size (µm)** | |
X-ray Tube, Jupiter Pkg, W, HP | 93000* | 8166 | W | 10 - 50 | 1.0 | 50 | 1.7 | 165 Max. | Add to quote list |
X-ray Tube, Jupiter Pkg, Mo, HP | 93001 | 8166 | Mo | 10 - 50 | 1.0 | 50 | 1.7 | 150 Typ. | Add to quote list |
X-ray Tube, Jupiter Pkg, Ag, STD | 93025 | 8166 | Ag | 4 - 50 | 1.0 | 50 | 1.3 | 1000 Typ. | Add to quote list |
X-ray Tube, Jupiter Pkg, Au, STD | 93035 | 8166 | Au | 10 - 50 | 1.0 | 25 | 1.3 | 1000 Typ. | Add to quote list |
X-ray Tube, Jupiter Pkg, Mo, STD, O-ring | 93046 | 8208 | Mo | 4 - 50 | 1.0 | 50 | 1.3 | 1000 Typ. | Add to quote list |
X-ray Tube, Jupiter Pkg, Cu, HP | 93048 | 8166 | Cu | 10 - 50 | 1.0 | 50 | 1.7 | 150 Typ. | Add to quote list |
X-ray Tube, Jupiter Pkg, Rh, HP | 93057 | 8166 | Rh | 10 - 50 | 1.0 | 50 | 1.7 | 180 Typ. | Add to quote list |
X-ray Tube, Jupiter Pkg, Rh, HP, VacFlange | 93059 | 8203 | Rh | 10 - 50 | 1.0 | 50 | 1.7 | 180 Typ. | Add to quote list |
X-ray Tube, Jupiter Pkg, W, HP | 93069* | 8166 | W | 10 - 50 | 1.0 | 50 | 1.7 | 70 Max. | Add to quote list |
X-ray Tube, Jupiter Pkg, Cr, HP | 93070 | 8166 | Cr | 10 - 50 | 1.0 | 50 | 1.7 | 200 Typ. | Add to quote list |
X-ray Tube, Jupiter Pkg, W, HP, VacFlange | 93071 | 8203 | W | 10 - 50 | 1.0 | 50 | 1.7 | 150 Typ. | Add to quote list |
X-ray Tube, Jupiter Pkg, Ti, STD | 93072 | 8166 | Ti | 4 - 50 | 1.0 | 50 | 1.3 | 1000 Typ. | Add to quote list |
X-ray Tube, Jupiter Pkg, Pd, HP | 93073 | 8166 | Pd | 10 - 50 | 1.0 | 50 | 1.7 | 200 Max. | Add to quote list |
X-ray Tube, Jupiter Pkg, Cu, HP, VacFlange | 93078* | 8203 | Cu | 10 - 50 | 1.0 | 50 | 1.7 | 175 Max. | Add to quote list |
X-ray Tube, Jupiter Pkg, Mo, HP, VacFlange | 93079* | 8203 | Mo | 10 - 50 | 1.0 | 50 | 1.7 | 150 Typ. | Add to quote list |
X-ray Tube, Jupiter Pkg, W, VHP | 93089* | 8166 | W | 10 - 50 | 1.0 | 50 | 1.7 | 50 Max. | Add to quote list |
X-ray Tube, Jupiter Pkg, Mo, VHP | 93095* | 8166 | Mo | 20 - 50 | 1.0 | 50 | 1.7 | 55 Max. | Add to quote list |
X-ray Tube, Jupiter Pkg, Fe, STD 2mA 50W | 93512* | 8166 | Fe | 4 - 50 | 2.0 | 50 | 1.4 | 1000 Typ. | Add to quote list |
Note: Part number specific copies of outline drawings and product specification sheets are available.
*Includes a thermal switch which adds an additional level of protection to the cooling system safeguards.
**Max. = Maximum, Typ. = Typical, Nom. = Nominal (per IEC60336,NEMA XR5-1999)